Hydrophobic IOLs are made with unique posterior edge design without compromising inherent optical properties of Intraocular lens.

Supra Phob

Introduction

SupraPhob is a new hydrophobic Intraocular lens made of premium quality Biocompatible Acrylic material and fabricated using Nano Resolution High Technology machine with tumble polishing. State of the art Preloaded system of SupraPhob makes the IOL's implantation simpler, faster & safer.

Special Features

  •  

    The advanced IOL design of SupraPhob yields excellent stability, so that even after the shrinkage of the Capsular Bag, the IOL remains well centered

  •  

    The advanced 360° Square Edge technology makes SupraPhob PCO free

  •  

    The UV blocking Chromophores of SupraPhob protects the retina from UV lights

  •  

    Each SupraPhob IOL is individually tested for high MTF which increases the accuracy & the quality of every IOL to its best

 

Preloaded System

None
 
  • 1
  • STAGE 1 Preloaded Delivery System inside the blister pack
 
  • 2
  • STAGE 2 Apply the viscoelastic as shown
 
  • 3
  • STAGE 3 When closing the cartridge flanges, Lens protecting cap will slide out from the system automatically
 
  • 4
  • STAGE 4 Close the cartridge. While closing the cartridge's flanges, you will hear a click sound that indicates its locked state.
 
  • 5
  • STAGE 5 Apply the  viscoelastic  from the front  barrel of the  cartridge up to  the pusher in  the injector,  before  implantation 
 
  • 6
  • STAGE 6 Now the system is ready to implant the lens
 

      

Technical Specification

Ref SPNT 200/300
Overall Length 13.00 mm
Optic Diameter 6.00 mm
Haptic Angulation
Optic Design Equi - Biconvex
Diopter Range 7D to 30D (0.5 Diopter)
Material Hydrophobic Acrylic
Delivery System Preloaded system
Special Features Aspheric Optics & 360° Square Edge
A Constant 118.8
Supra Phob BBY

Introduction

SupraPhob BBY is a hydrophobic yellow intraocular lens made of premium quality Biocompatible Acrylic material. Fabricated by the State of the Art of the Technology machine with Froze-tumble polish. Uncomplicated Preloaded system of SupraPhob Lens is easy and enjoyable feel to implant the Hydrophobic Acrylic Lens safer.

Special Features

  •  

    The advanced IOL design of SupraPhob BBY yields excellent stability, so that even after the shrinkage of the Capsular Bag, the IOL remains well centered

  •  

    The advanced 360° Square Edge technology makes SupraPhob BBY Lens PCO free

  •  

    The UV blocking Chromophores of SupraPhob BBY protects the retina from UV lights

  •  

    Each Supraphob BBY is individually tested for optical Quality (MTF).

 

Preloaded System

None
 
  • 1
  • STAGE 1 Preloaded Delivery System inside the blister pack
 
  • 2
  • STAGE 2 Apply the viscoelastic as shown
 
  • 3
  • STAGE 3 When closing the cartridge flanges, Lens protecting cap will slide out from the system automatically
 
  • 4
  • STAGE 4 Close the cartridge. While closing the cartridge's flanges, you will hear a click sound that indicates its locked state.
 
  • 5
  • STAGE 5 Apply the  viscoelastic  from the front  barrel of the  cartridge up to  the pusher in  the injector,  before  implantation 
 
  • 6
  • STAGE 6 Now the system is ready to implant the lens
 

      

Technical Specification

Ref SPNT 200Y/300Y
Overall Length 13.00 mm
Optic Diameter 6.00 mm
Haptic Angulation
Optic Design Equi - Biconvex
Diopter Range 7D to 30D (0.5 Diopter)
Material Hydrophobic Acrylic
Delivery System Preloaded system
Special Features Aspheric Optics & 360° Square Edge
A Constant 118.0

        

Supra Phob Toric

Introduction

SupraphobToric is the next generation Toric IOL, made up of premium quality biocompatible Yellow Hydrophobic Acrylic material with the refractive index of 1.49. It is fabricated by Nano Technology Polish Free High Technology Machine.

  •  

    The non-touch preloaded system makes IOL implantation simple

  •  

    Each curvature on the Toric has an Aspherical Design

  •  

    Markings are made on the anterior surface corresponding to the flat meridian of the lens

  •  

    Each marking is made by the diamond tool at 4.5 mm of the optic for easy viewing and positioning

 

Preloaded System

None

 
  • 1
  • STAGE 1 Preloaded Delivery System inside the blister pack
 
  • 2
  • STAGE 2 Apply the viscoelastic as shown
 
  • 3
  • STAGE 3 When closing the cartridge flanges, Lens protecting cap will slide out from the system automatically
 
  • 4
  • STAGE 4 Close the cartridge. While closing the cartridge's flanges, you will hear a click sound that indicates its locked state.
 
  • 5
  • STAGE 5 Apply the  viscoelastic  from the front  barrel of the  cartridge up to  the pusher in  the injector,  before  implantation 
 
  • 6
  • STAGE 6 Now the system is ready to implant the lens
 

Special Features

  •  

    Ultraviolet Filtering Chromophores for better protection of Retina from UV light

  •  

    State of the art technology of SupraphobToric makes sure that its optical performance is equal to that of a natural, young, crystalline lens

  •  

    The BLUE BLOCKING YELLOW feature prevents ARMD

Astigmatism Correction

  •  

    Supraphob Toric’s Astigmatism correction IOL is available from +10.00D to +30.00D; the difference between any two  Dioptres being 0.50D

  •  

    The AppaToric IOL calculator compensates for the expected  Surgically Induced Astigmatism and directly impacts the amount of and/or the axis of Post-Incisional Astigmatism that has to be corrected

Toric IOL Calculator

  •  

    Considers the effect of Incision Location and Surgically Induced Cylinder to make a more precise calculation

  •  

    Determines the correct IOL model and Optimal Axis Placement of the IOL in the capsular bag

REFCYLINDER POWERCORNEAL PLANE
SP TORIC T3 1.50 1.03
SP TORIC T4 2.25 1.55
SP TORIC T5 3.00 2.06
SP TORIC T6 3.75 2.57
SP TORIC T7 4.50 3.08
SP TORIC T8 5.25 3.60
SP TORIC T9 6.00 4.11

Technical Specification

Overall Length 13.00 mm
Optic Diameter 6.00 mm
Haptic Dual Haptic, 0° angulation prevents rotation after implants
Optic Design Biconvex, Aspheric Toric on anterior surface
Diopter Range
Spherical 10.00D to 30.00D (0.5D increment)
Cylinder 1.50D to 6.00D
Material Hydrophobic Yellow Acrylic
Refractive Index 1.497
Delivery System Ready to inject preloaded system
Special Features Aspheric Optics with 360° Square Edge
A Constant 118.0

    

Supra Phob Regen

Supra Phob Regen

SUPRAPHOB-REGEN is a new generation diffractiver efractivemultifocal Intraocular Lens designed to offer EXCELLENT VISION TO  THE PATIENTS undergoing CATARACT  SURGERY providing independence from Spectacles.

Quality & Accuracy

  •  

    All lenses are tested for Resolution with Air Force Target immediately after Lathing

  •  

    Each "Regen" is individually tested with Optical Bench Sytem called IOLA-MFD for power, quality and MTF for testing near and far focal points

  •  

    Each “Regen" is assured of higher MTF values. Higher the MTF value, higher the contrast from all distances and under all light conditions

 
  •  

    It is made of premium quality Biocompatible Hydrophobic Acrylic Material fabricated by Nano Resolution High Technology machine with minimum polishing.

  •  

    "Regen" is a diffractive-refractive combined multifocal lens, ensuring good vision from all distances.

  •  

    To top it all, the Advanced Preloaded System makes the IOL implantation simpler & safer.

Clear Vision at All Distances

  •  

    With the years of experience in multifocal IOL design, we have come up with the addition of +3.5D power to separate the near & distant images and to make them distinctive

  •  

    The light is evenly distributed between all focal points (near, intermediate & distant) resulting in a crystal clear vision from all distances

  •  

    The central zone is of 4.2mm diameter has 20 diffractive zones. The remaining 1.8mm portion of the lens has the refractive zone

The IOL is designed in such a way that the step height gradually declines towards the periphery. This guarantees excellent satisfaction for the patients allowing them to enjoy the Crystal Clear Vision under all light conditions

PCO

Each "Regen" has 360° Square Edge, Posteriorly offering excellent barrier to PCO

Special Features

  •  

    The overall Haptic and Optic design offers excellent centration of IOL irrespective of the capsular bag’s size

  •  

    The Negative Asphericity provided in Regen affords better visual quality than any other Spherical IOL

  •  

    The Regen IOL has Ultraviolet filtering chromophores for better protection of retina from UV light

  •  

    The Regen IOL has Ultraviolet filtering chromophores for better protection of retina from UV light

  •  

    State of the art technology of "Regen" ensures that its optical performance is equal to that of a young, natural, crystalline lens

  •  

    The unique anterior diffractive design reduces the halos and yields superior vision

  •  

    Owing to the superior quality of the hydrophobic material, the posterior capsule securely adheres to the rear surface of the lens. The anterior placement of diffractive optics protects optical properties from YAG laser

Technical Specification

Ref SPNT200MF
Overall Length 13.00 mm
Optic Diameter 6.00 mm
Haptic Angulation
Optic Design Equi-biconvex, with diffractive anterior surface
Diopter Range 7.00D TO 30.00D (0.5D increment)
Material Yellow Hydrophobic Acrylic
Refractive Index 1.497
Delivery System Ready to inject preloaded
Special Features Aspheric Optics with 360° Square Edge
A Constant 118.0

SupraPhobRegen